The 35 & 60 series products are mercury displacement relays. Sealed tubes containing liquid mercury assure contact surfaces are freshly replenished with every contact movement. Contact resistance is among the lowest available for any electromechanical relay. The M35 series offers superior long life performance. Products are available with 1, 2, or 3 poles rated 35 amps. Contacts can be normally open or normally closed.

Optional DIN rail adaptors – 1 pole = 16-MDRDIN-1, 2 or 3 pole = 16-MDRDIN-2/3

Additional contact configurations and coil options are available – please use the RFQ/RFI tab above to submit your request.
UL Listed & CSA
Unit of Measure

Specifications

Series

M60

Contact Arrangement

AA (2 N.O. tube)

Coil Voltage

24 VAC

Stocked PN

WM60AA-24AC

Contacts

Contact Configuration

Up to 3PST

Contact Material

Liquid Mercury

Contact Rating

60 A

Contact Rating 120 / 240VAC Resistive

60 A

Contact Rating 28VDC Resistive

60 A

Motor 120VAC 1 Phase

5 hp

Motor 240VAC 1 Phase

10 hp

Contact Resistance, Initial

50 milliohms max at 6VDC

Coil

Coils Available

AC and DC

Nominal Coil Power AC

7 to 28 VA

Nominal Coil Power DC

3 to 9 W

Input Voltage Tolerance - AC

85% to 110% of nominal

Input Voltage Tolerance - DC

80% to 110% of nominal

Drop-out voltge

10% of nominal

Duty

Continuous

Timing

Operate Time (max)

50 ms

Release Time (max)

80 ms

Dielectric Strength

Across Open Contacts

2650 Vrms

Between Mutually Insulated Point

2650 Vrms

Insulation Resistance

1000 megohms at 500VAC

Temperature

Operating

-34 to 74 ºC-30 to 165 ºF

Storage

-40 TO 105 ºC-40 to 221 ºF

Life Expectancy

Electrical (full load)

250,000

Mechanical (no load)

5,000,000

Miscellaneous

Mounting Position

Vertical within 10 degrees

Enclosure

Hermetically Sealed

Weight

varies