
| Items |
193RE1A3-12G 193 Series - Dry Miniatrue Reed Relays |
193RE1A3-5S 193 Series - Dry Miniatrue Reed Relays |
193RE2A3-12G 193 Series - Dry Miniatrue Reed Relays |
193RE2A3-6G 193 Series - Dry Miniatrue Reed Relays |
193RE2C3-24G 193 Series - Dry Miniatrue Reed Relays |
|||||
| Series | N/A 193 | |||||||||
| Contact Arrangement | N/A SPST - N.O. | N/A SPST - N.O. | N/A DPST - N.O. | N/A DPST - N.O. | N/A DPDT | |||||
| Nominal Input Voltage | N/A 12 VDC | N/A 5 VDC | N/A 12 VDC | N/A 5/6 VDC | N/A 24 VDC | |||||
| Maximum Pull-in | N/A 9 | N/A 4 | N/A 9 | N/A 4 | N/A 18 | |||||
| Minimum Dropout | N/A 1 | N/A 0.5 | N/A 1 | N/A 0.5 | N/A 2 | |||||
| Nominal Resistance | N/A 420 Ω | N/A 500 Ω | N/A 280 Ω | N/A 70 Ω | N/A 1500 Ω | |||||
| Nominal Power | N/A 350 mW | N/A 50 mW | N/A 500 mW | N/A 360 mW | N/A 390 mW | |||||
| Maximum Switching Load | N/A 10 VA | N/A 10 VA | N/A 10 VA | N/A 10 VA | N/A 3 VA | |||||
| Switching Current and Voltage | N/A 0.5 Amps 200VDC | N/A 0.5 Amps 200VDC | N/A 0.5 Amps 200VDC | N/A 0.5 Amps 100VDC | N/A 0.25 Amps 100VDC | |||||
| Carry Current | N/A 2 A | N/A 2 A | N/A 2 A | N/A 2 A | N/A 1 A | |||||
| Contact Configuration | N/A Up to 4PDT | |||||||||
| Contact Material | N/A Rhodium | |||||||||
| Contact Rating | N/A xPST | N/A xPST | N/A xPST | N/A xPST | N/A xPDT | |||||
| Contact Rating Load (maximum) | N/A 10 VA | N/A 10 VA | N/A 10 VA | N/A 10 VA | N/A 4 VA | |||||
| Contact Rating Switching Voltage (maximum) | N/A 200 VDC | N/A 200 VDC | N/A 200 VDC | N/A 100 VDC | N/A 120 VDC | |||||
| Contact Rating Switching Current (maximum) | N/A 0.5 A | N/A 0.5 A | N/A 0.5 A | N/A 0.5 A | N/A 0.25 A | |||||
| Contact Rating Carry Current (maximum) | N/A 3.5 A | N/A 3.5 A | N/A 3.5 A | N/A 3.5 A | N/A 1 A | |||||
| Contact Resistance, Initial | N/A 100 milliohms max at 6VDC | N/A 100 milliohms max at 6VDC | N/A 100 milliohms max at 6VDC | N/A 100 milliohms max at 6VDC | N/A 150 milliohms max at 6VDC | |||||
| Coils Available | N/A DC | |||||||||
| Coil Power | N/A Varies | |||||||||
| Input Voltage Tolerance - DC | N/A 80% to 110% of nominal | |||||||||
| Drop-out voltge | N/A 10% of nominal | |||||||||
| Duty | N/A Continuous | |||||||||
| Operate Time (typical w/o suppression) | N/A 1 ms | |||||||||
| Release Time (typical w/o supression) | N/A 1 ms | |||||||||
| Across Open Contacts | N/A 200 Vrms | |||||||||
| Between Mutually Insulated Point | N/A 500 Vrms | |||||||||
| Insulation Resistance | N/A 1000 megohms at 100VDC | |||||||||
| Capacitance Across Open Contacts | N/A 3pF | |||||||||
| Operating | N/A -40 to 125 ºC-40 to 200 ºF | |||||||||
| Storage | N/A -40 to 200 ºC-40 to 392 ºF | |||||||||
| Electrical (full load) | N/A 10,000,000 | |||||||||
| Mechanical (no load) | N/A 100,000,000 | |||||||||
| Mounting Position | N/A any | |||||||||
| Enclosure | N/A Epoxy Encapsulated | |||||||||
| Weight | N/A varies | |||||||||
|
|
||||||||||